Interfeys
Portlarning umumiy soni 5
L2 darajasini almashtirish
RJ45 tipidagi o'ralgan juft ulagich
Texnologiyalar
10BaseT uchun IEEE 802.3, 100BaseT(X) va 100BaseFX uchun IEEE 802.3u, Oqimlarni boshqarish uchun IEEE 802.3x, Spanning Tree Protocol uchun IEEE 802.1D-2004, IEEE 802.10. Class uchun, SIEEEp18 802.1 VLAN teglari uchun Q
EtherNet/IP, Modbus/TCP sanoat protokollari
Boshqaruv protokollari IPv4/IPv6, SNMP v1/v2c/v3, LLDP, Port Mirror, RMON, DHCP Server/mijoz, DHCP opsiyasi 66/67/82, BootP, TFTP, SMTP, RARP, Telnet, Syslog, SNMP Inform, Flow Control , Orqa bosim oqimini boshqarish
Filtrlash protokollari 802.1Q VLAN, Portga asoslangan VLAN, GVRP, IGMP v1/v2, GMRP
Ortiqcha protokollar STP, RSTP, Turbo Ring v1/v2, Turbo Chain
Vaqtni sinxronlashtirish protokollari SNTP, NTP Server/Client
IEEE 802.3x oqim nazorati, orqa bosim oqimini boshqarish
MAC manzillar jadvali 2000
Paket buferi hajmi 1 Mbit
Tez chekilgan 10/100 Mbit / s portlar
Buralgan juftlik (RJ45 ulagichi) 5
Rele chiqishi
O'rni chiqish kanallari soni 1
O'rnimizni yuklash quvvati 24 VDC da 1 A ni tashkil qiladi.
Aqlli funktsiyalarni qo'llab-quvvatlash
Elektr uzilishi to'g'risida avtomatik xabar berish O'rni yordamida, E-Mail orqali, SNMP orqali
Port orqali ulanishning noto'g'riligi to'g'risida avtomatik xabar berish Relay yordamida, E-Mail orqali, SNMP orqali
LED ko'rsatkichlari
LED ko'rsatkichlari PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL, 10/100M
Qurilma boshqaruvi
Boshqarish interfeysi RS-232 konsoli
RS-232 RJ45 konsol port ulagichi
MIB-asoslari MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
DIP kalitlari Turbo Ring, Master, Coupler, Reserve
Quvvat talablari
Ish kuchlanishi 12/24/48 V DC. (9,6 ~ 60V DC)
24 V da joriy iste'mol 0,21 A
Zaxira quvvat manbasini ulash imkoniyati Ha
Quvvat ulagichi terminali
Teskari polaritdan himoyalanish Ha
foydalanish shartlari
Ishlash harorati, °C 0 ~ +60
Saqlash harorati, °C -40 ~ +85
Ishlash namligi, % 5 ~ 95
Himoya
Chang va namlikdan himoya qilish IP30
Joriy himoya Ha
Dizayn xususiyatlari
Korpus materiali metall
O'lchamlari va vazni
Umumiy o'lchamlari, mm 54 x 135 x 105
Sof og'irligi, kg 0,65
O'rnatish
DIN temir yo'lini o'rnatish
Stol usti/devorga o'rnatilgan (ixtiyoriy)
Xalqaro sertifikatlarning mavjudligi
Xavfsizlik CSA C22.2 №. 60950-1
UL508
UL60950-1
Portlashdan himoyalangan ATEX zonasi 2 Ex nA nC IIC T4 Gc
UL/cUL 1-sinf 2-bo‘lim
Elektromagnit moslik (EMI) CISPR 32
FCC 15-qism B kichik bo'limi A sinfi
Elektromagnit moslik (EMS) IEC 61000-4-2 (ESD)
IEC 61000-4-3 RS
IEC 61000-4-4 (EFT)
IEC 61000-4-5 Ko'tarilish
IEC 61000-4-6 CS
IEC 61000-4-8
Elektromagnit moslik (EMC) EN 55032/24
DNV dengiz tizimlarida qo'llanilishi
GL
NEMA TS2 Transport ilovalari
Ta'sirlar IEC 60068-2-27
Erkin tushish IEC 60068-2-32
Tebranishlar IEC 60068-2-6
Nosozliklar orasidagi o'rtacha vaqt (MTBF), soat 852421
Kafolat muddati
Kafolat muddati 5 yil
Yetkazib berish to'plami
Yetkazib berish to'plami Foydalanilmayotgan portlar uchun vilkalar
RJ45 - DB9 konsol kabeli
Tez boshlash uchun qo'llanma
Qurilma