Process temperature
115 … 135 °C , < 1 h
-40 … 115 °C , permanent
Output range
-50 … 150 °C , programmable
Min. output span
25 °C
Pt100 accuracy class (EN 60751)
B (± 0.3 °C at 0 °C)
A (± 0.15 °C at 0 °C)
AA (± 0.1 °C at 0 °C)
1/6 B (± 0.05 °C at 0 °C)
Max. conversion error
± 0.25 °C
Max. output error
± 0.1 % FS
± 0.016 mA
Temperature drift (by ambient)
< 0.003 % FS/°C , typ.
< 0.01 % FS/°C , max.
Response time, T90
≤ 6.5 s , 20 mm
≤ 6.7 s , 50 mm
≤ 66.0 s , front-flush
Response time, T50
≤ 2.5 s , 20 mm.
≤ 2.7 s , 50 mm
≤ 9.0 s , front-flush
Sampling interval
0.5 s
Process connection
Immersion length
0 mm , front-flush
20 mm
50 mm
Sensor tube material
AISI 316L (1.4404)
Wetted parts material
PEEK Natura
Surface roughness wetted parts
Ra ≤ 0.8 µm
Ambient conditions
Degree of protection (EN 60529)
IP 67
IP 69K , with appropriate cable
Humidity
< 98 % RH , condensing
Vibration (sinusoidal) (EN 60068-2-6)
1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
Output signal
Without transmitter
Pt100, 4-wire
With transmitter
4 … 20 mA , 2-wire
Shunt resistance
Rs ≤ (Vs — 8 V)/0.023 A
Rs ≤ 680 Ohm, Vs = 24 V DC
Compliance and approvals
EMC
EN 61000-6-2
EN 61000-6-3
EN 61326-1
Hygiene
10/2011/EU
1935/2004/EG
2023/2006/EG
3-A (74-06)
FDA (21 CFR 177.2415)
© 2012 - 2024 glotr.uz. Все права защищены